Technology Glossary

Technology glossary



Auto-Gating Lux
Black Spots - Blemishes Lumen
Brightness Gain Magnification
Bright Spots Microamps per Lumen (uA/lm)
Collimation Microchannel Plate (MCP)
Distortion MILSPEC
Equivalent Background Illumination (EBI) Near-Infrared
Fiber Optic Inverter Output Brightness Variation
Field-of-View Phosphor Screen
Figure of Merit (FOM) Photoresponse
Fixed Pattern Noise (FPN) Photocathode
Gain Photosensitivity (Photoresponse)
Gallium Arsenide (GaAs) Resolution
Generations of Image Intensifiers RMA
Honeycomb Screen
Image Disparity Signal-to-Noise Ratio (SNR)
Image Distortion Scintillation
Line Pairs per Millimetre (lp/mm) System Gain


Auto-Gating - Auto-Gating is the electronic solution that reduces the duty cycle of the cathode voltage by rapidly switching the voltage on and off. It is a proprietary means to preserve the high MTF (Modulation Transfer Function) and resolution that is obtained at the full operating voltage while reducing the strain of high illumination levels on the image intensifier tube. This is done by reducing the average current coming from the photocathode. Auto-Gating constantly operates to improve the quality of the image, not only during day-night-day transition, but also under dynamic lighting conditions such as military operations in urban terrain which define many of today's missions. Auto-Gating is standard on XR5 and optional on XD-4 Image Intensifier Tubes.
Click here to see a 3D animation about how Auto-Gating works
Top
Black Spots - Blemishes- Cosmetic blemishes in the image intensifier or dirt/debris between the lenses. Black spots in the image intensifier do not affect the performance or reliability of the device and are inherent in the manufacturing processes
Top
Brightness Gain - When referring to an image intensification tube, brightness gain is the ratio of the brightness of the output in units of lm/cm2
Top
Bright Source Protection (BSP) - An electronic function that reduces the voltage to the photocathode when the night vision device is exposed to bright light sources such as room lights or car lights. BSP protects the image tube from damage and enhances its life. However, BSP may have the effect of lowering resolution when it is functioning
Top
Bright Spots. These are signal- induced blemishes in the image area caused by a flaw in the film on the MCP. A bright spot is small, non- uniform, bright area that may flicker or appear constant. Bright spots usually go away when the light is blocked out. Not all bright spots make the ANVIS unserviceable. A test can be performed as follows: Place a cupped hand over the lens to block out all light. Make sure any bright spot is not simply a bright area in the viewed scene. If the bright spot remains, an emission point exists and needs to be checked.
Top
Collimation - The act of making rays of light travel in parallel lines. Also the process of aligning the various internal optical axes of a system with each other.
Top
Convergence - The shifting of an observer's eyes inward to view a nearby object i.e. crossing the eyes.
Top
Chicken Wire - An irregular pattern of dark lines in the image area or in parts of the image area. Under the worse condition, these lines will form hexagonal or square-wave shaped lines.
Top
Distortion - Three types of distortion are most significant to night vision devices: geometric, "S" and sheer.
  • Geometric Distortion - is inherent in all Gen 0 (infrared Tubes ie. B-20) and Gen I image intensifiers and in some Gen II image intensifiers that use electrostatic rather than fibre-optic inversion of the image. Geometric distortion is eliminated in image tubes that use a microchannel plate and fibre-optics for image inversion, however, some S-distortion can occur in these tubes.
  • S-Distortion - results from the twisting operation in manufacturing fibre-optic inserters ). Usually S-Distortion is very small and is difficult to detect with the unaided eye.
  • Sheer Distortion - can occur in any image tube that uses fibre-optic bundles for the phosphor screen. It appears as a cleavage or dislocation in a straight line viewed in the image area as through the line were sheered
Top
Electronic Noise - Also known as Scintillation. A faint, random, sparkling effect throughout the image area. Scintillation is a normal characteristic of microchannel plate image intensifiers and is more pronounced under low-light-level conditions
Top
Equivalent Background Illumination (EBI) - This is the amount you see in an image tube that is turned on but there is no light at all on the photocathode; it is affected by temperature where the warmer night-vision device, the brighter the background illumination. EBI is measured in lumens per square centimetre (lm/cm2) wherein the lower the value the better. The EBI level determines the lowest light level at which you can detect something. Below this light level, objects will be masked by the EBI.
Top
Fiber Optic Inverter - A bundle of microscopic light transmitting fibers twisted 180 degrees.
Top
Field-of-View (FOV) - The width or spatial angle of the outside scene that can be viewed through the intensifier tubes measured laterally and vertically. Typical NVGs have a 40° FOV. There are NVGs in development that attempt to increase this FOV significantly in an effort to enhance pilot performance. An example of a wide FOV NVG would be the Panoramic NVGs'.
Top
Figure of Merit (FOM) - Image Intensification tube specification designation, calculated on line pair per mm X signal to noise. The US government applies FOM as a method of controlling Image Intensified equipment.
Top
Fixed Pattern Noise (FPN) - A faint hexagonal (honeycomb) pattern throughout the image area that most often occurs under high-light conditions. This pattern is inherent in the structure of the microchannel plate and can be seen in virtually all Gen II and Gen III systems if the light level is high enough.
Top
Gain - Also called brightness gain or luminance gain. This is the number of times an image intensifier tube amplifies light input. It is usually measured as tube gain and system gain. In any night vision system, the tube gain is reduced by the system's lenses and is affected by the quality of the optics or any filters; therefore, system gain is a more important measurement to the user.
Top
Gallium Arsenide (GaAs) - The semiconductor material used in manufacturing of the Gen III photocathode.
Top
Generations of Image Intensifiers - Image intensifier tubes are classed by generation (GEN) numbers assigned by the US Army's Night Vision Laboratory. Each GEN denotes a new contract or manufacturing process.
Note: Generations do not define the performance specs of the image intensifier.
  • Generation I
    It started with electrostatically focused Generation I tubes featuring high image resolution, a wide dynamic range and low noise
  • Generation II
    Introduced the Micro Channel Plate for much higher gain in the 1980’s. The original image resolution was less than that of the first generation intensifiers but the gain was much higher
  • Generation III
    In the late 1980’s an Image Intensifier with a GaAs photocathode was developed showing an enhanced sensitivity in the Near-Infrared. In the late 1990’s Gen III tubes with greatly improved performance appeared on the market. These types are called Gen III Omni III and Gen III Omni IV.

PHOTONIS introduced the new European Standard for low light-level imaging in 1996. This new performance family brings superior performance which exceeds the performance of GEN III image intensifiers.

Top
Honeycomb - See Fixed-Pattern Noise.
Top
Image Disparity - This condition may exist when there is a difference in brightness between the two image intensifier assemblies within the same binocular.
Top
Image Distortion - This problem is more easily detected in high- light conditions. Image distortion is evidenced by vertical objects, such as trees or poles appearing to wave or bend when the user moves his head vertically or horizontally when looking through the goggles. Ground surfaces in the direction of hover may appear to swell or sink. Distortion does not change during life of an image intensifier. Limits on allowable distortion are an important part of performance specifications since excess distortion can interfere with viewing the image and thus with the operator’s ability to perform necessary flight maneuvers.
Top
Line Pairs per Millimetre (lp/mm) - Units used to measure image intensifier resolution. Usually determined from a 1951 Air Force Resolving Power test target. The target is a series of different sized patterns composed of three horizontal and three vertical lines. The lines and spacing between lines in each of the different patterns differ in width; the narrower the width, the greater the resolution is needed to distinguish the lines in a given pattern. Human test subjects must be able to clearly distinguish all the horizontal and vertical lines of a particular pattern in order for an image intensifier to achieve the resolution represented by that pattern.
Top
Lumen - The unit denoting the photons (light) perceivable by the human eye in one second.
Top
Lux - A unit measurement of illumination. The illuminance produced on a surface that is on meter square, from a uniform point source of one-candela intensity, or one lumen per square meter.
Top
Magnification - The magnifying power of the lens. Four power (4X) indicates that the image will appear four times larger than if viewed with a 1X lens.
Top
Microamps per lumen - The measure of electrical current (A) produced by a photocathode when it is exposed to a measured amount of light (lumens).
Top
Microchannel Plate (MCP) - A metal coated glass disk that multiplies the electrons produced by the photocathode. PHOTONIS SAS produces MCP's with 11 million pores and is constantly developping and improving the performance of the MCP for enhanced image intensifier tube performance. Electrons entering the channel strike a wall and knock off additional electrons which in turn knock off more electrons, producing a cascading effect. MCPs eliminate the distortion characteristic of GEN I systems. The number of holes in an MCP is a major factor in determining resolution.
Top
MILSPEC - Term for Military Specification. It is the minimum acceptable requirements for products procured by the US Department of Defence. Use of the term MILSPEC indicates that the product meets applicable military specifications.
Top
Near-Infrared - The shortest wavelengths of the infrared region, normally 750 to 2,500 nanometers (nm). GEN II operates from around 440 to 950 nanometers.
Top
Output Brightness Variation - This condition is evidenced by areas of varying brightness in or across the image area. The lower contrasts do not exhibit distinct lines of demarcation nor do they degrade image quality. This condition should not be confused with shading.
Top
Phosphor Screen -The phosphor screen converts electrons into photons. A very thin layer of phosphor is applied to the output fiber optic system, and emits light when struck by electrons. See also Photocathode.
Top
Photocathode - The input surface of an image intensifier that absorbs light energy and in turn releases electrical energy in the form of an electron image. The type of material used is a distinguishing characteristic of the generations of image intensifiers.
Top
Photoresponse (PR) - See Photosensitivity.
Top
Photosensitivity (Photoresponse) - Also called photocathode sensitivity or photoresponse. The ability of the photocathode material to produce an electrical response when subjected to light waves (photons). Usually measured in microamps of current per lumen (mA/lm).
Top
Resolution - The ability of an image intensifier or night vision system to distinguish between objects close together. Image intensifier resolution is measured in line pairs per millimetre (lp/mm) while system resolution is measured in cycles per miliradian. For any particular night vision system, the image intensifier resolution will remain constant while the system resolution can be affected by altering the objective or eyepiece optics by adding magnification or relay lenses. Often the resolution in the same night vision device is very different when measured at the centre of the image and at the periphery of the image. This is especially important for devices selected for photograph or video where the entire image resolution is important. Measured in line pairs per millimetre (lp/mm).
Top
RMA - Range Migration Algorithm
Top
Signal-to-Noise Ratio (SNR) - A measure of the light signal reaching the eye divided by the perceived noise as seen by the eye. A tube's SNR determines the low-light-resolution of the image tube; therefore, the higher the SNR, the better the ability of the tube to resolve objects with good contrast under low-light conditions. Because SNR is directly related to the photocathode's sensitivity and also accounts for phosphor efficiency and MCP operating voltage, it is the best single indicator of an image intensifier's performance
Top
Scintillation - Also known as electronic noise. A faint, random, sparkling effect throughout the image area. Scintillation is a normal characteristic of microchannel plate image intensifiers and is more pronounced under low-light-level conditions
Top
Screen- The image tube output that produces the viewable image. Phosphor (P) is used on the inside surface of the screen to produce the glow, thus producing the picture. Different phosphors are used in image intensifier tubes, depending on manufacturer and tube generation.
Top
System Gain- Equal to tube gain minus losses induced by system components such as lenses, beam splitters and filters